Carrier 30rw 080 Manual

080

This brand new Carrier Comfort 95 59SC5A080S17-16 Gas Furnace offers a ten year limited parts. Carrier 59SC5A080S0 BTU, Up To 95%. Product Manuals. Carrier 30rw 080 manual =1&eintraege_pro_seite=469&beginn= carrier air cooled chiller 30ra 080 30ra Scroll Air Water Chiller 30ra 160 A compiled pdf, doc. Condenser fans (30RB080-390 with Greenspeed technology) Features/Benefits Carrier’s superior chiller design provides savings at initial purchase, at installa.

. 30RW/RWA Water-Cooled/Condenserless Liquid Chillers with Integrated Hydronic Modules Nominal cooling capacity 20-310 kW 50 Hz Installation, operation and maintenance instructions. Contents 1 - IntRoDUCtIon.4 1.1 - Installation safety considerations.4 1.2 - Equipment and components under pressure.5 1.3 - Maintenance safety considerations.5 1.4 - Repair safety considerations.6 2 - PRelImInaRy CheCks.7 2.1 - Check equipment received. 10 - ConDenseR wateR flow Rate.29 10.1 - Condenser pump flow/pressure curve.29 10.2 - Available static system pressure (condenser side).29 11 - 30Rw UnIt oPeRatIon wIth a DRyCooleR. 30 11.1 - Operating principle.30 11.2 - Auxiliary electronic analogue input and output and discrete output board (AUX1) for control of the drycooler. 1 - INTRODUCTION DO NOT COVER ANY PROTECTION DEVICES. Prior to the initial start-up of the 30RW/30RWA units, the This applies to fuse plugs and safety valves (if used) in the people involved in the on-site installation, start-up, operation refrigerant or heat transfer medium circuits.

Check if the and maintenance of this unit should be thoroughly familiar original protection plugs are still present at the valve outlets. 1.2 - Equipment and components under pressure Operating checks: IMPORTANT INFORMATION REgARDINg ThE These products incorporate equipment or components under pressure, manufactured by Carrier or other manufacturers.

REFRIgERANT USED: We recommend that you consult your appropriate national. This product contains fluorinated greenhouse gas trade association or the owner of the equipment or compo- covered by the Kyoto protocol. 1.4 - Repair safety considerations Avoid spilling liquid refrigerant on skin or splashing it into the eyes.

Use safety goggles and safety gloves. Wash All installation parts must be maintained by the personnel in any spills from the skin with soap and water. If liquid charge, in order to avoid material deterioration and injuries refrigerant enters the eyes, immediately and abundantly to people. 2.2 - Moving and siting the unit Use only original replacement parts for any repair or compo- nent replacement.

Asco mp-c-080 manualCarrier 30rw 080 Manual

Kubota Kx 080 Manual Quick Couplers

Consult the list of replacement parts that corresponds to the specification of the original equipment. 2.2.1 - moving Do not drain water circuits containing industrial brines, See chapter 1.1 - “Installation safety considerations”. For these checks national regulations must be followed. If. Verify the free passage of access and safety routes. The national regulation does not specify any details, refer. Check that ventilation in the plant room is adequate.

To standard EN 378-2 as follows:. 3.2 - 30RW/30RWA 020-045 - unit with hydronic module (option) and/or unit with option 116E (Victaulic water connection at the top) 30RW 020-030 30RW 040-045 1-1/4” Gas 2” Gas 1-1/4” Gas 2” Gas 1204 3.3 - 30RW/30RWA 060-150 - unit with or without hydronic module 2004 legend: NOTE: Non-contractual drawings. 3.4 - 30RW/30RWA 160-300 - unit without hydronic module (standard) 2300 1100 2013 (RW) - 2048 (RWA) 3.5 - 30RW/30RWA 160-300 - unit with hydronic module (option) 2950 1100 legend: NOTE: Non-contractual drawings. Refer to the certified dimensional drawings. All dimensions are in mm. Water inlet For the positioning of the fixing points, weight distribution and centre of gravity coordinates, also refer to the certified. 4 - PHySICAl AND ElECTRICAl DATA 4.1 - Physical data 30RW/RWA Nominal cooling capacity 30RW.

20.2 25.9 29.9 39.7 45.3 56 30RWA. 24.4 28.2 37.8 43.5 54 Operating weight 30RW weight without hydronic module 1079 1144 1357 1471 1421 1491 30RWA weight without hydronic module kg 1000 1318 1318 1361 1371 Extra weight. The neutral (N) conductor must not be connected directly to the unit (if. The Carrier 30RW and 30RWA units are designed and built to ensure necessary use a transformer).

Conformance with these codes. The recommendations of European standard.